ארכיון מכשיר לבדיקת בילירובין - עמיאל באלאנס https://abalance.co.il/product-category/ציוד-רפואי/מכשיר-לבדיקת-בילירובין/ עמיאל באלאנס Mon, 15 Apr 2024 11:10:42 +0000 he-IL hourly 1 https://wordpress.org/?v=6.7.1 https://abalance.co.il/wp-content/uploads/2023/09/cropped-עמיאללוגו-32x32.pngארכיון מכשיר לבדיקת בילירובין - עמיאל באלאנסhttps://abalance.co.il/product-category/ציוד-רפואי/מכשיר-לבדיקת-בילירובין/ 32 32 BiliCare מכשיר למדידת רמות הבילירובין ליילודיםhttps://abalance.co.il/product/bilicare/ https://abalance.co.il/product/bilicare/#respond Sun, 25 Feb 2024 16:06:13 +0000 https://abalance.co.il/?post_type=product&p=1418Neonatal jaundice is a common condition, but if not carefully monitored, hyperbilirubinemia can lead to kernicterus, a devastating condition. Early measurement of bilirubin levels leading to early intervention is recommended, but the time to collect a blood sample and the trauma to the baby made universal screening difficult. Now the BiliCareTM System offers a cost- […]

הפוסט BiliCare מכשיר למדידת רמות הבילירובין ליילודים הופיע לראשונה ב-עמיאל באלאנס.

]]>
Neonatal jaundice is a common condition, but if not carefully monitored, hyperbilirubinemia can lead to kernicterus, a devastating condition. Early measurement of bilirubin levels leading to early intervention is recommended, but the time to collect a blood sample and the trauma to the baby made universal screening difficult. Now the BiliCareTM System offers a cost- and time-effective way to monitor bilirubin levels without unnecessary heel pricks.

The BiliCareTM System measures bilirubin levels using patented technology that provides accurate results. The technology is based on spectroscopy. The system measures the transcutaneous bilirubin level of the newborn by sending light at different wavelengths through the auricle. The amount of light absorbed by bilirubin is calculated using a custom algorithm.

• Less sensitive to motion artifacts
• Insensitive to pressure differences or changes in the angle of the device

… read more
The LED advantage
LEDs do not deteriorate over time. No shift in power or ave length means no routine calibration is required. The optional calibration check allows the user to confirm calibration if desired. The calibration verification process is quick and easy and provides immediate results.

Communication features
BiliCare includes communication functions that can connect it to a PC and/or a HIS via HL-7

BiliCareTM Viewer
Unique B/W displaying results in tables and charts. These can be printed and exported.

הפוסט BiliCare מכשיר למדידת רמות הבילירובין ליילודים הופיע לראשונה ב-עמיאל באלאנס.

]]>
https://abalance.co.il/product/bilicare/feed/ 0